武田機電

 

LOHER低壓防爆電機 Ex nA Ex e Ex d(e)

Loher motors in Ex nA Regarding explosion protection, for Ex nA II motors, the risk of arcing and sparking or hot surfaces during normal operation is prevented with an appropriate motor design therefore guaranteeing the required degree of safety. Motors with type of protection "non sparking nA" are used in explosive atmospheres, whereby, this atmosphere may occur in a potentially hazardous quantity. These motors are assigned to equipment group II - Category 3G (this corresponds to Zone 2). Loher Ex nA II motors are certified and optimally adapted for use in hazardous Zone 2 according to EN 50014 and EN 50021 or EN 60079-0 and EN 60079-15. They are stamped with II 3 G Ex nA II according to EC Directive (94/9/EC). The EC Declaration of Conformity documents that these regulations have been complied with. What is worth noting: According to EN 60079-15:2005, a risk assessment must be made for all motors with rated voltages above 1 kV. Loher has successfully completed the type test for the stator and rotor according to EN 60079-15:2005. As a consequence, normally no additional measures are required up to 11 kV. With Loher motors, the complex purging process before the motor started can be eliminated. When required, Ex nA motors also fulfill regulations relating to dust explosion protection according to EN 50281-1-1 // EN 50281-1-2. They are then additionally designated and documented with an EC type test certificate if the motors are operated in an environment with conductive dust. For variable-speed drives (converter operation), a type test must be performed with the actual converter intended for the application.

Loher motors in Ex e The basic idea behind this type of protection against explosion is to avoid the generation of sparks and arcs or excessively high motor temperatures by applying a series of measures so that there is no possibility of ignition in the first place. In addition, a suitable monitoring device is always required that even under fault conditions (e.g. locked rotor) avoids any ignition. Motors with type of protection "increased safety e" are located in an explosive atmosphere, whereby, this atmosphere may occur in a potentially hazardous quantity. These motors are assigned to equipment group II - Category 2G (this corresponds to Zone 1). They guarantee a high degree of safety. Loher Ex e motors are certified and optimally adapted for use in hazardous zone 1 according to EN 50014 and EN 50019 or EN 60079-0 and EN 60079-7. They are stamped with II 2 G Ex e II according to the EC Directive (94/9/EC). An EC type test certificate guarantees that the regulations are always maintained. Ex e motors also fulfill - if required - the regulations relating to explosion dust protection according to EN 50281-1-1 // EN 50281-1-2 and are then correspondingly additionally type tested and documented with an EC type test certificate if the motor is to operate in an environment with conductive dust.

Loher motors in Ex d(e) Motors with this type of protection against explosion are designed so that a possible explosion remains restricted to the inside of the motor. This means that the enclosure must be able to withstand the pressure from an explosion. In order to define the hazard as a result of an explosive gas (in comparison to other degrees of protection), in addition to the ignition temperature, it is also necessary to specify the capability of an igniting flame to be transmitted through a narrow gap in the motor enclosure. This is realized by classifying them in explosion groups IIA, IIB, IIC. Motors with type of protection "flameproof enclosure d" are located in an explosive atmosphere, whereby this atmosphere may occur in a potentially hazardous quantity. These motors are assigned to equipment group II - Category 2G (this corresponds to Zone 1). They guarantee a high degree of safety.Loher Ex d(e) motors are certified and optimally adapted for use in hazardous Zone 1 according to EN 50014, EN 50018, EN 50019 or EN 60079-0, EN 60079-1 and EN 60079-7. They are stamped with III 2 G Ex d IIB, II 2 G Ex d IIC according to the EC Directive (94/9/EC). (When the terminal box is designed and constructed to comply with increased safety with II 2 G Ex de IIB, II 2 G Ex de IIC.) An EC type test certificate always guarantees that the regulations are maintained and complied with. Ex d(e) motors also fulfill - if required - the regulations relating to dust explosion protection according to EN 50281-1-1 // EN 50281-1-2 and are then correspondingly additionally type tested and documented with an EC type test certificate if the motor is to operated in an environment with conductive dust.

 

 
  香港及海外業務:  00852-27828783 傳真:00852-30119987
中國大陸地區業務:021-51085793  傳真:021-51086107   電郵:wsitl@21cn.net
     
主站蜘蛛池模板: 国产精品一区亚洲 | 国产成人yy精品在线 | 欧美一区永久视频免费观看 | 国产一级毛片国语一级 | 大陆一级毛片视频 | 久久久久久久久久美女 | 欧美一级特黄aa大片 | 国产精品乱码久久久久 | 水蜜桃亚洲一二三四在线 | 毛片久久久久 | 91精品免费在线观看 | 99精品国产闺蜜国产在线闺蜜 | 欧美城网站地址 | 秋霞鲁丝片无码一区二区 | 国产精品99久久久久人最新消息 | 夜色资源网wwwwwww免费看 | 亚洲xxx视频 | 亚洲精品中文综合第一页 | FREE性玩弄少妇HD性老妇 | 偷偷操不一样的久久 | 亚洲国产精品成人无久久精品 | 国产精品v欧美精品v日韩精品 | 色姑娘天天综合网 | 中文字幕一区二区三区日韩 | 国产精品高清一区二区三区不卡 | 国产乱淫视频免费 | 国产免费啪视频观看网站 | 欧美日韩综合一区二区在线观看视频 | 国产精品成人网站在线观看 | 免费精品视频一区 | 国产日韩欧美视频免费看 | 国产精品女同一区二区三区 | 亚洲无码av一区2区三区四区 | 国产精品久久久久久一区二区三区 | 黄色1级大片 | 99久久精品日本一区二区免费 | 亚洲影视第一页 | 91麻豆产精品久久久久久 | 国产乱子伦农村叉叉叉 | 黄片毛片一级片 | se吧提供在线看片免费人成久网 |